Back to top
English

A reliable and predictive model of an existing structure entails the use of model updatingtechniq...ues,whichareusuallyperformedonthebasisofoperationalmodalanalysis campaigns. In this paper, a new model calibration strategy is proposed that adopts a multiphysics approach to exploit data collected by both static and dynamic monitoring systems. More specifically, mechanical and temperature data are assimilated into the model through a thermoelastic updating. The proposed scheme is validated with numerical simulations and applied on the Sanctuary of Vicoforte, a complex historical building that is subjected to both static and dynamic monitoring.

Publication type: 
Journal Articles
Evidence for R3C: 
N
Publication Date: 
Friday, December 31, 2021
Cluster: 
Preserving Cultural Heritage
Year: